Operating Controls
Broiler Functionality Programming
Operating Controls
Broiler Functionality Programming
¾ Idle temperature-temp set point during preheat and idle cycles
-range 500-900 degrees F
-factory preset 680 degrees F
¾ Offset parameter-Difference between measured temp and display temp
-Positive offset-display temp will be below measured temp
-Negative offset-display temp will be above measured temp
¾ Chain drive time-time required for chain to complete ½ rotation
-range 1-10 seconds
-factory default 6 seconds
-factory default right to left